CNG delivery | Glycol bath PRS

PRS-G2000

The PRS-G2000 is the PRS-G8000 design scaled to 2,000 MSCF/d: the same glycol bath heating, redundant two-stage pressure control, onboard fuel gas and automation in a smaller package. Heater duty and flow are scaled from the PRS-G8000; footprint and weight are confirmed per unit.

Overview

CNG delivered from trailers arrives at high pressure and drops sharply on its way to site pressure. That pressure drop cools the gas fast enough to freeze regulators, valves and downstream equipment if the heat is not put back in. The PRS-G2000 puts it back with a about 500 MBTU/hr glycol bath heater sized for continuous delivery up to 2,000 MSCF/d.

Redundant control valve (stage 1) and Mooney regulator (stage 2) circuits keep gas flowing even during maintenance. User-definable outlet PSVs and onboard fuel gas mean the unit ships ready to drop on site, hook up and run. Trailer swap logic, multi-trailer mode and start-up sequencing are handled in software.

PRS-G series pressure reduction skid, control valve and regulator piping
PRS-G series piping in the NuBlu shop: stage 1 control valve circuits and stage 2 regulator circuits ahead of the glycol bath heater.

Key specifications

Pressure cuts2-stage standard (3 and 4 stages optional)
Heater typeGlycol bath, about 500 MBTU/hr
Flow rate120 to 2,000 MSCF/d
Inlet pressureUp to 4,200 psig (CNG trailer service)
Outlet pressureUser defined, set per application
Pressure controlRedundant control valve circuits (stage 1), redundant Mooney regulator circuits (stage 2)
TurndownLarge turndown, extremely low delta-P
Overpressure protectionUser-definable outlet PSVs
Fuel gasOnboard fuel gas system for the heater burner
AutomationFully automated PLC with HMI, remote monitoring via Ewon
FootprintSkid or trailer mounted, sized to the unit
Design standardsASME Section VIII Div. 1, B31.3, NEC, NFPA
SkidSingle skid, fully assembled and FAT-tested in shop

Heater duty and flow are scaled from the PRS-G8000. Final outlet pressure, valve trim, PSV settings, footprint and weight are confirmed per unit. Contact engineering for a sized proposal.

Why PRS-G2000

Glycol bath heating

About 500 MBTU/hr glycol bath heater sized for continuous 2,000 MSCF/d delivery. Keeps gas above hydrate and freeze conditions even during sustained high-flow operation.

Redundant pressure control

First-stage cut by two parallel control valve circuits, second-stage cut by two parallel Mooney regulator circuits. Run on one, service the other. No shutdown for routine maintenance.

Mobile package

Skid or trailer mounted and sized to the unit, designed to move between sites and operate wherever CNG trailers are staged.

Fully automated

PLC-based control with HMI and remote monitoring via Ewon. Trailer swap logic, multi-trailer mode and start-up sequencing handled in software.

Onboard fuel gas

Self-supplied fuel gas for the heater burner. No external fuel hookup required to start producing heat.

Built and tested in shop

Final assembly, FAT, loop checks and HMI commissioning happen in our shop. Issues get caught in the shop, not on your site.

Typical applications

  • Dual-fuel frac and e-frac fleets
  • Drilling rig fuel gas supply
  • Mobile and temporary power generation
  • Pipeline integrity work and pipeline pack-up
  • Peak shaving and standby gas service
  • Remote site CNG-to-line-pressure conversion

What's included

  • Skid-mounted skid with glycol bath heater, control valves and process piping
  • Stage 1 control valve and stage 2 Mooney regulator circuits, redundant
  • User-definable outlet PSVs
  • Onboard fuel gas system
  • PLC, HMI and field instrumentation, wired and tested
  • Trailer-swap and multi-trailer control logic
  • Cause-and-effect diagram, control narrative and FAT package
  • ASME-stamped pressure vessels, B31.3 piping
  • Installation, commissioning and start-up procedure
  • Recommended spare parts list and pricing

Engineering and aftermarket support

Every PRS-G2000 ships with a complete engineering package: P&IDs, GA drawings, electrical load lists and a full O&M manual. Critical spares, including control valve trims and instrumentation, are stocked at our shop for fast response.

Field service, troubleshooting and remote diagnostics are handled by the same team that designed and built the unit.

The PRS family: pick the heat source, then the capacity

PRS-G series

Glycol bath heater. High-volume, continuous duty with reliable heating.

PRS-C series

Catalytic heater. Flame-free, compact, no separate fuel hookup.

PRS-E series

Electric heater. Utility and LDC sites where open flame is not an option.

Ready to size it?

Send us your suction pressure, flow target, outlet pressure or project scope. We come back with a configured package, usually within one business day.